Boilers

Boilers2026-11-11T08:15:29+00:00

Showing: BOILERS Kalvis · Show all

Katel Kalvis-2-20N

Katel Kalvis-2-20NKalvis-2-20N
Output: 20kW
Heated area: up to 250m2
Fuel: halupuu, up to 40cm
Water volume: 72l
H/W/D: 1350x770x1210mm
Flue: Ø160mm
Weight: 360kg
Price: 2950 EUR
Website

Katel Kalvis-2-16N

Katel Kalvis-2-16NKalvis-2-16N
Output: 16kW
Heated area: up to 200m2
Fuel: halupuu, up to 35cm
Water volume: 46l
H/W/D: 1160x670x1180mm
Flue: Ø160mm
Weight: 325kg
Price: 3219€
Website

Pelletkatel Kalvis K-8-16DG

Pelletkatel Kalvis K-8-16DGKalvis K8-16DG
Output: 5-16kW
Heated area: up to 267(560)m2
Fuel:pellet(Ø6-8mm)
Water volume: 70 l
Container: 155 l
H/W/D: 1320x635x1045mm
Flue: Ø160mm
Price: 5457€

Pelletkatel Kalvis K-8-20DG

Pelletkatel Kalvis K-8-20DG

Kalvis K8-20DG
Output: 5-20kW
Heated area: up to 334 (700)m2
Fuel:pellet(Ø6-8mm)halupuu
Water volume: 74 l
Container: 155 l
H/W/D: 1380x615x940mm
Flue: Ø160mm
Weight: 276kg
Price: 5742€

Pelletkatel Kalvis K-2-12DG

Pelletkatel Kalvis K-2-12DG

Kalvis-2-12NDG
Output: 5-12kW
Heated area: up to 200 (420)m2
Fuel:pellet(Ø6-8mm)halupuu
Water volume: 28l
H/W/D: 880x630x1200mm
Flue: Ø160mm
Weight: 253kg
Price: 4774€

Puukatel Kalvis K-5-12(10)

Puukatel Kalvis K-5-12(10)

Puukatel Kalvis K-5-12 (10)

Kalvis-5-12(10)
Output: 10-12kW
Heated area: up to 132 m2
Fuel: halupuu, up to 33cm
Water volume: 32l
H/W/D: 1010x470x620mm
Flue: Ø130mm
Weight: 165kg
Price: 1355€

Hübriidkatel Kalvis K2-40NDG

Hübriidkatel Kalvis K2-40NDG

Kalvis-2-40-NDG
Output: 10-40kW
Heated area: up to 668 (1400)m2
Fuel:pellet(Ø6-8mm)halupuu
Water volume: 80l
H/W/D: 1360x930x1600mm
Flue: Ø180mm
Weight: 605kg
Price: 8930€

Puukatel Kalvis K-2-12N

Puukatel Kalvis K-2-12N

Puukatel Kalvis K-2-12N

Kalvis-2-12N
Output: 12kW
Heated area: 55-252 m2
Fuel: halupuu, up to 30cm
Water volume: 28l
H/W/D: 880x630x980mm
Flue: Ø160mm
Weight: 202kg
Price: 2317€

 

Puukatel Kalvis K-2-30N

Puukatel Kalvis K-2-30N

Puukatel Kalvis K-2-30N

Kalvis-2-30N
Output: 30kW
Heated area: 220-380 m2
Fuel: halupuu, up to 40cm
Water volume: 103l
H/W/D: 1450x770x1340mm
Flue: Ø180mm
Weight: 552kg
Price: 3500€

Puukatel Kalvis K-2-40N

Puukatel Kalvis K-2-40N

Tahkeküttekatel Kalvis K-2-40N

Kalvis-2-40N
Output: 40kW
Heated area: 184-840 m2
Fuel: halupuu, up to 45cm
Water volume: 80l
H/W/D: 1360x930x1290mm
Flue: Ø180mm
Weight: 595kg
Price: 3699€

Hübriidkatel K-2-30-NDG

Hübriidkatel K-2-30-NDG

Kalvis-2-30-NDG
Output: 8-30kW
Heated area: up to 534 (1120)m2
Fuel:pellet(Ø6-8mm)halupuu
Water volume: 103l
H/W/D: 1450x770x1340mm
Flue: Ø180mm
Weight: 592kg
Price: 7859€

Hübriidkatel K-2-20-NDG

Hübriidkatel K-2-20-NDG

Kalvis-2-20-NDG
Output: 5-20kW
Heated area: up to 334 (700)m2
Fuel:pellet(Ø6-8mm)halupuu
Water volume: 72l
H/W/D: 1350x790x1570mm
Flue: Ø160mm
Weight: 385kg
Price: 5225€

Hübriidkatel K-2-16NDG

Hübriidkatel K-2-16NDG

Kalvis-2-16-NDG
Output: 5-16kW
Heated area: up to 267 (560)m2
Fuel:pellet(Ø6-8mm)halupuu
Water volume: 46l
H/W/D: 1160x690x1400mm
Flue: Ø160mm
Weight: 360kg
Price: 5905€

Katel Kalvis -5-8(6)

Katel Kalvis -5-8(6)Kalvis-5-8(6)
Output: 6-8kW
Heated area: up to 90m2
Fuel: halupuu, up to 30cm
Water volume: 18l
H/W/D: 790x410x620mm
Flue: Ø120mm
Weight: 112kg
Price: 1053€
Website

Central heating boilers and their installation guide

The boiler may only be installed in a boiler room that meets the requirements of “EVS 812-3 Fire safety of buildings. Part 3: Heating systems”. The boiler may only be lifted by supporting it under the base frame. The water flow/return pipe on top of the boiler is connected to the heating system with a four-way mixing valve or a special manifold. The flue pipe of the boiler is connected to the chimney with the shortest possible flue run, sloping upwards. The central heating boiler is suitable for both closed and open heating systems and for heating water. When equipped with a suitable distribution/control system, the boilers are also suitable for underfloor heating and domestic hot water.

The burner, selected according to the seller’s recommendations, is mounted on the firebox door in accordance with the burner’s installation instructions. The burner must be compatible with the boiler. The opening in the firebox door is made for the most common pellet burners, but doors with special solutions can also be ordered. When installing the boiler, the requirements of the Pressure Equipment Safety Act and the regulations and guidelines based on it must be met. Questions that arise when installing the boiler and fitting it with equipment should be resolved together with a heating engineer. After installation, it is advisable to test the boiler to determine the most suitable operating modes and thermal efficiency.

User guide

The boilers are designed for burning wood pellets or light heating oil. The boiler operates without the constant supervision of an operator. The boilers work with an automatic pellet or oil burner, which is used in accordance with the burner’s user manual. For maximum efficiency, the boilers are designed to be used with the turbulators fitted in them. At an output of 20 kW the boilers require a chimney draught of 10–20 Pa. If the natural draught of the chimney is insufficient, a flue gas draught fan must be installed. The water operating pressure in the boiler must not exceed 2.5 bar.

Control, monitoring and safety devices. The circuit breaker in the boiler’s connection circuit must be 6 A for an oil or gas burner and 10 A for a pellet burner. The limit switch of the firebox door stops the burner if the door is open for more than 60 seconds. The maximum temperature thermostat stops the burner when the boiler water reaches 95 °C; the burner can only restart when the water temperature has dropped and the thermostat has been reset manually. The safety valve opens when the water pressure in the boiler exceeds 2.5 bar; to check that it works, open it manually by its handle. The power plug connects the boiler’s electrical system to the mains and must be plugged into a three-pin earthed socket. The burner connector is supplied with the burner.

Boiler maintenance

When burning pellets, the turbulator shaker lever is moved to clean the flue tubes and turbulators; this can be done while the boiler is running. As a guide, the turbulators should be cleaned once a week. To ensure normal operation, after burning about 500 kg of pellets clean the burner grate and firebox and empty the ash pan – the boiler must be stopped for this. A thorough service once a year is recommended. To clean the heating surfaces, open the top hatch, shake loose ash off the turbulators, remove the shaker axles, pull out the turbulators and clean them with a brush. Soot deposited in the flue tubes is also removed with a suitable brush, after first pushing the soot and ash in the upper smoke chamber down through the tubes into the firebox. When cleaning the firebox, also clean the burner grate and empty the ash pan. When burning pellets, the boiler must also be cleaned if the flue gas temperature has risen above 230 °C or the draught has noticeably deteriorated. Follow the manufacturer’s recommendations and instructions for normal burner operation. At the end of the winter heating season, clean the boiler thoroughly to prevent soot from caking on the heating surfaces. When burning light heating oil, the boiler should be cleaned once a year at the end of the heating season.

The owner is responsible for the safe operation of the boiler and must: keep the boiler room clean and tidy; ensure a proper connection between the boiler and the chimney; ensure the chimney is in good condition. It is strictly forbidden to: fire the boiler without water; fill a hot boiler that has run dry with water; store easily flammable materials in the boiler room.

Electrical connections

The connection to the mains may only be made by a qualified electrician. A flexible cable with a cross-section of 3/5 × 1.5 mm² should be used. The appliance is designed for a 230 V supply and requires a fuse of max. 10 A.

Recommendations for choosing boiler turbulators

As the turbulators in the convection tubes are the main source of aerodynamic resistance, they should be chosen according to the parameters of the customer’s chimney. Boilers with a pellet burner and turbulators require a chimney draught of 10 Pa (1 mm WC) at 20 kW and 20 Pa at 30 kW. With a stronger draught, turbulators with a higher number are recommended. As chimney draught depends on many factors, it is always advisable to measure it and choose the boiler turbulators accordingly. Turbulators are made with four different aerodynamic resistances – the higher the number, the greater the resistance. A turbulator with greater resistance gives the boiler a higher efficiency.