Boilers2026-11-11T08:15:29+00:00

Showing: BOILERS Termomont · Show all

Pelletkatel TKU3

Pelletkatel TKU3Pelletkatel TKU3-w põletiga
TERMEC-50kW,mahuti 180kg
20 kW – 2900 EUR
25 kW – 2960 EUR
30 kW – 3020 EUR
35 kW – 3100 EUR
40 kW – 3160 EUR
50 kW – 3300 EUR
Technical data

Keskküttekatel TKK3 Max

kaminad,ahjud,pliidid,katlad,saunaahjud,korstnad,korsten,moodulkorstnad

Keskküttekatel TKK3 Max

Keskküttekatel TKK3 Max
(tahkel küttel)
TKK3 100kW – 6090 EUR
TKK3 200kW – 9465 EUR
TKK3 250kW – 10410 EUR
TKK3 300kW – 12300 EUR
Technical data

Keskküttekatel TKU3

Keskküttekatel TKU3

Keskküttekatel TKU3

Keskküttekatel TKU3
(tahkel küttel)
TKU3  20kW  –  2069 EUR
TKU3  25kW  –  2157 EUR
TKU3  30kW  – 2325 EUR
TKU3  35kW  – 2415 EUR
TKU3  40kW – 2640 EUR
TKU3  50kW – 2903 EUR
Technical data

Pelletkatel TKK3

kaminad,ahjud,pliidid,katlad,saunaahjud,korstnad,korsten,moodulkorstnad

Pelletkatel TKK3

Pelletkatel TKK3põletiga
TERMEC-100kW, mahuti
300kg
70kW – 5194 EUR
90kW – 5440 EUR
100kW- 6545 EUR
Technical data

Central heating boilers and their installation guide

The boiler may only be installed in a boiler room that meets the requirements of “EVS 812-3 Fire safety of buildings. Part 3: Heating systems”. The boiler may only be lifted by supporting it under the base frame. The water flow/return pipe on top of the boiler is connected to the heating system with a four-way mixing valve or a special manifold. The flue pipe of the boiler is connected to the chimney with the shortest possible flue run, sloping upwards. The central heating boiler is suitable for both closed and open heating systems and for heating water. When equipped with a suitable distribution/control system, the boilers are also suitable for underfloor heating and domestic hot water.

The burner, selected according to the seller’s recommendations, is mounted on the firebox door in accordance with the burner’s installation instructions. The burner must be compatible with the boiler. The opening in the firebox door is made for the most common pellet burners, but doors with special solutions can also be ordered. When installing the boiler, the requirements of the Pressure Equipment Safety Act and the regulations and guidelines based on it must be met. Questions that arise when installing the boiler and fitting it with equipment should be resolved together with a heating engineer. After installation, it is advisable to test the boiler to determine the most suitable operating modes and thermal efficiency.

User guide

The boilers are designed for burning wood pellets or light heating oil. The boiler operates without the constant supervision of an operator. The boilers work with an automatic pellet or oil burner, which is used in accordance with the burner’s user manual. For maximum efficiency, the boilers are designed to be used with the turbulators fitted in them. At an output of 20 kW the boilers require a chimney draught of 10–20 Pa. If the natural draught of the chimney is insufficient, a flue gas draught fan must be installed. The water operating pressure in the boiler must not exceed 2.5 bar.

Control, monitoring and safety devices. The circuit breaker in the boiler’s connection circuit must be 6 A for an oil or gas burner and 10 A for a pellet burner. The limit switch of the firebox door stops the burner if the door is open for more than 60 seconds. The maximum temperature thermostat stops the burner when the boiler water reaches 95 °C; the burner can only restart when the water temperature has dropped and the thermostat has been reset manually. The safety valve opens when the water pressure in the boiler exceeds 2.5 bar; to check that it works, open it manually by its handle. The power plug connects the boiler’s electrical system to the mains and must be plugged into a three-pin earthed socket. The burner connector is supplied with the burner.

Boiler maintenance

When burning pellets, the turbulator shaker lever is moved to clean the flue tubes and turbulators; this can be done while the boiler is running. As a guide, the turbulators should be cleaned once a week. To ensure normal operation, after burning about 500 kg of pellets clean the burner grate and firebox and empty the ash pan – the boiler must be stopped for this. A thorough service once a year is recommended. To clean the heating surfaces, open the top hatch, shake loose ash off the turbulators, remove the shaker axles, pull out the turbulators and clean them with a brush. Soot deposited in the flue tubes is also removed with a suitable brush, after first pushing the soot and ash in the upper smoke chamber down through the tubes into the firebox. When cleaning the firebox, also clean the burner grate and empty the ash pan. When burning pellets, the boiler must also be cleaned if the flue gas temperature has risen above 230 °C or the draught has noticeably deteriorated. Follow the manufacturer’s recommendations and instructions for normal burner operation. At the end of the winter heating season, clean the boiler thoroughly to prevent soot from caking on the heating surfaces. When burning light heating oil, the boiler should be cleaned once a year at the end of the heating season.

The owner is responsible for the safe operation of the boiler and must: keep the boiler room clean and tidy; ensure a proper connection between the boiler and the chimney; ensure the chimney is in good condition. It is strictly forbidden to: fire the boiler without water; fill a hot boiler that has run dry with water; store easily flammable materials in the boiler room.

Electrical connections

The connection to the mains may only be made by a qualified electrician. A flexible cable with a cross-section of 3/5 × 1.5 mm² should be used. The appliance is designed for a 230 V supply and requires a fuse of max. 10 A.

Recommendations for choosing boiler turbulators

As the turbulators in the convection tubes are the main source of aerodynamic resistance, they should be chosen according to the parameters of the customer’s chimney. Boilers with a pellet burner and turbulators require a chimney draught of 10 Pa (1 mm WC) at 20 kW and 20 Pa at 30 kW. With a stronger draught, turbulators with a higher number are recommended. As chimney draught depends on many factors, it is always advisable to measure it and choose the boiler turbulators accordingly. Turbulators are made with four different aerodynamic resistances – the higher the number, the greater the resistance. A turbulator with greater resistance gives the boiler a higher efficiency.