Fireplace inserts

Fireplace inserts2026-11-11T08:13:15+00:00

A fireplace insert is the firebox around which a fireplace of your own design is built. It is the right choice if you want a fireplace built into a wall or in a specific place. A central heating fireplace insert also heats water for radiators in addition to the room. The range includes single-glass, corner and three-sided inserts as well as central heating fireplace inserts. We will help you choose the right output and chimney – visit our showroom in Tallinn or Pärnu or ask for advice.

Showing: FIREPLACE INSERTS Invicta · Show all

Kaminasüdamik Invicta 700 Optimise

Kaminasüdamik Invicta 700 Optimise

Kaminasüdamik Invicta 700 Optimise

Output: 7,5kW
Height: 506mm
Width: 690mm
Depth: 340mm
Flue diameter: 200mm
Weight: 98kg
Price: 598 EUR
Price: 498 EUR

KAMINASÜDAMIK dANGLE VD P626372

KAMINASÜDAMIK dANGLE VD P626372

KAMINASÜDAMIK
dANGLE VD P626372
Vasak või parem nurk
Output:6-13,5 kw nom. 9 kW
Height:685 mm
Width:652 mm
Depth:443 mm
Flue diameter: 200 mm
Weight:98 kg
Price: 1508 EUR
Price: 1431 EUR

 

Invicta 1100 Grande Vision Relevable

Invicta 1100 Grande Vision Relevable

Kaminasüdamik 1100 Grande Vision Relevable

Invicta 1100 Grande
Vision Relevable
Output: 20 KW
Height: 1158 mm
Width: 1100 mm
Depth: 522 mm
Flue diameter: Ø 230 mm
Price: 3010 EUR

Invicta 900 Grande Vision Relevable

Invicta 900 Grande Vision Relevable

Kaminasüdamik 900 Grande Vision Relevable 6890-44

Invicta 900 Grande
Vision Relevable

Output: 18 KW
Height: 1158 mm
Width: 900 mm
Depth: 540 mm
Flue diameter: Ø 200 mm
Price: 2546 EUR

Kaminasüdamik Invicta 700 Compact

Kaminasüdamik Invicta 700 Compact

Kaminasüdamik Invicta 700 Compact

Output: 12 kw
Height: 747 mm
Width: 694 mm
Depth: 464 mm
Weight:128 kg
Flue: 200 mm
Price: 1035 EUR

700 Selenic kolme klaasiga

kaminad,ahjud,pliidid,katlad,saunaahjud,korstnad,korsten,moodulkorstnad

700 Selenic kolme klaasiga

700 Selenic kolme klaasiga
Output:14 kw
Height:690 mm
Width:692 mm
Depth:455 mm
Weight:134 kg

700 Selenic

700 SelenicKaminasüdamik 700 Selenic siibriga
Output:10 kw
Height:664 mm
Width:692 mm
Depth:491 mm
Kaal.125 kg
Price: 880 EUR

700 Double Face

kaminad,ahjud,pliidid,katlad,saunaahjud,korstnad,korsten,moodulkorstnad

700 Double Face

700 Double Face
Output:14 kw
Height:870 mm
Width:696mm
Depth:460 mm
Weight:141 kg
Price: 1529 EUR

800 Grande Vision Double Face

kaminad,ahjud,pliidid,katlad,saunaahjud,korstnad,korsten,moodulkorstnad

800 Grande Vision Double Face

800 Grande Vision Double Face
Output:15 kw
Kõrgus.950 mm
Width:795 mm
Sügavus.510 mm
Weight:164 kg
Price: 1772 EUR

Invicta 900 Grande Vision

kaminad,ahjud,pliidid,katlad,saunaahjud,korstnad,korsten,moodulkorstnad

900 Grande Vision

900 Grande Vision
Output:18 kw
Height:1158 mm
Width:900 mm
Depth:490 mm
Weight:215 kg
Price: 1795 EUR

Invicta 1100 Grande Vision

kaminad,ahjud,pliidid,katlad,saunaahjud,korstnad,korsten,moodulkorstnad

1100 Grande Vision

1100 Grande Vision
Output:18 kw
Height:1158 mm
Width:1100 mm
Depth:519 mm
Weight:265 kg
Price: 1920 EUR

Invicta 840 Horisontaal

kaminad,ahjud,pliidid,katlad,saunaahjud,korstnad,korsten,moodulkorstnad

840 Horisontaal

840 Horisontaal
Output:14 kw
Height:698 mm
Width:846 mm
Depth:435 mm
Weight:125 kg
Price: 1180 EUR

What a fireplace insert is for

A fireplace insert is designed to be built in and is used as an additional heat source in the room where it is installed.

Choosing a fireplace insert

The output of a fireplace insert depends on how well the room is insulated and on the volume to be heated. As a rule of thumb, for a sufficiently insulated room 1 kW of output is enough for 10 m² of floor area with a standard ceiling height (2.5 m). You can always consult our fireplace specialists.

Installing a fireplace insert

Installation of a fireplace insert must comply with applicable legislation, standards, the manufacturer’s instructions and good building practice. The installation should be carried out by a specialist or a qualified company and must comply with national and local regulations.

Chimney flues

Fireplace inserts should be connected to a separate chimney flue in accordance with applicable legislation. It is recommended that:

  • the minimum height of the flue is 3.5–4 m, optimally 5–6 m, measured from the firebox;
  • the flue is leak-tight, has the same diameter along its entire length and rises about 0.5 m above the ridge of the roof so as not to impede the draught;
  • in special situations (wind load zones II and III, local topography) chimney cowls that prevent smoke from blowing back are used.

Attention! If the chimney flue:

  • is smaller than recommended,
  • is located on a building in an unfavourable position (e.g. near high-rise buildings or in a valley),
  • deviates from the vertical and/or has long horizontal sections,

the required negative pressure (draught) may be missing, so flue gases are not drawn out and the fireplace insert smokes. Before installing a fireplace insert, a chimney sweep should assess the draught of the flue and whether the existing flue can be connected to the insert. The draught of the chimney should be 12 ± 2 Pa. A flue with a draught above 12 Pa can cause the insert to overheat and void the warranty. The minimum draught should be 6 ± 1 Pa.

Ventilation and air supply

In rooms where flue gases from fireplace inserts are removed by natural draught, mechanical extract ventilation is not permitted, with the exception of heat recovery units. When a fireplace insert is in use, the room must be supplied with sufficient air: at least 10 m³/h for every 1 kW of the insert’s nominal output. An insufficient air supply causes incomplete combustion, and flue gases containing carbon monoxide and soot may cause smoke. This is dangerous to life and health, reduces the output of the insert and is not grounds for a warranty claim.

Before installation, check that the insert is complete, that all mechanisms work and that the body is sound. The insert should be installed on a non-combustible base at least 0.15 m thick. The floor in front of the door must be protected with a strip of non-combustible material that ensures safe use (at least 0.6 m and no shorter than the length of the open door).

When building the casing of a fireplace insert you must:

  • install the insert on surfaces with sufficient load-bearing capacity;
  • allow air to circulate between the walls of the insert and the casing – leave a gap of at least 6 cm between the fire-resistant insulation of the casing walls and the ribbed surface of the insert;
  • ensure air reaches the insert through an air grille above it (the grille must be designed so that it cannot become blocked);
  • ventilate the insert with a pressure relief grille with an area of 200 cm²; the decompression chamber should be 30–50 cm high, measured from the ceiling;
  • keep a distance of at least 150 cm between the front of the insert and combustible materials;
  • remove all external and safety elements;
  • leave the clearances needed for cleaning the insert and its connector.

After installation, the fireplace insert should be handed over with an acceptance report. Leave at least 6 cm between the insert and the insulation (measured from the ribbed surface to the insulation), and 2–3 cm between the upper part of the facade and the elements of the insert body. Missing these clearances can cause damage and loss of the warranty.

Lighting a fireplace insert for the first time

The first fire should be lit only after the building materials used have dried. Do not make a fierce fire the first time, to avoid a sudden change in temperature. During the first firing a special smell appears – this is the protective coating curing. The smell disappears after a few firings. When lighting, open the primary air supply fully and close it gradually as the fire gets going.

Using a fireplace insert

Safety. Take special care when using a fireplace insert because of the high temperature – there is a risk of burns and fire:

  • use the protective glove supplied by the manufacturer when handling the insert;
  • do not let children near the insert unless supervised by an adult;
  • never dismantle the insert or make any changes to its construction;
  • do not put out the fire in the insert with water;
  • a carbon monoxide detector is recommended in the room where the insert is installed;
  • never leave a burning fire unattended;
  • do not use the insert to dry materials (e.g. clothes), including in its vicinity;
  • never burn fuel in an insert that has not been built in;
  • the door must be closed during normal operation.

If soot ignites in the chimney, notify the nearest fire brigade and a chimney sweep. Until they arrive, fight the fire with a powder extinguisher, directing the jet straight into the chimney flue.

Adjusting the air supply

Combustion can be regulated with the controls provided for this purpose:

  • the position of the handle that opens the damper, which regulates the draught;
  • the position of the slide on the front of the ash pan, which regulates the air supply to the bottom of the firebox.

Firewood for fireplace inserts

Fireplace inserts (depending on the model) burn wood or hardwood briquettes. The heating value of wood is 3.5–3.7 kW/kg when its moisture content is below 20%. Only wood with a moisture content of no more than 20% is suitable – this is reached after about two years of storage. Freshly cut wood has a moisture content of 50–60%. Burning it not only doubles fuel consumption but also causes corrosion of the insert’s parts, rapid soiling of the glass and deposits of soot (creosote) in the insert and flue. Use only the recommended fuel. Do not fill the firebox completely – the optimal amount is about one third of its height. Burning anything other than recommended wood, especially waste and liquid fuels, is prohibited.

Maintenance and cleaning

A fireplace insert must be cleaned regularly, paying particular attention to the flue pipes. A technical inspection by a chimney sweep twice a year is recommended. Chimney flues need to be checked for leaks and swept by a chimney sweep once a year, paying particular attention to whether the flue is clear (it may be blocked by birds’ nests, leaves, etc.). Clean the glass only with products intended for this purpose; regular cleaning prevents permanent stains. Use liquids so that the seals of the insert do not get wet. Remove the ash before the ash pan is completely full, so that it does not block the air supply and the cooling of the grate.

Go to Top