A fireplace insert is the firebox around which a fireplace of your own design is built. It is the right choice if you want a fireplace built into a wall or in a specific place. A central heating fireplace insert also heats water for radiators in addition to the room. The range includes single-glass, corner and three-sided inserts as well as central heating fireplace inserts. We will help you choose the right output and chimney – visit our showroom in Tallinn or Pärnu or ask for advice.

Kaminasüdamik Echatech 3V 80 G

Kaminasüdamik Echatech 3V 80 G

Kaminasüdamik Echatech 3V 80 G

Echatech 3V 80 G
Output: 14kW
Height: 1385mm
Width: 860mm
Depth: 580mm
Flue diameter: 200mm
Weight: 245kg
Flue gas: 175°C
Price: 3333 EUR

Kaminasüdamik Echatech 3V 90 C G

Kaminasüdamik Echatech 3V 90 C G

Kaminasüdamik Echatech 3V 90 C G

Echatech 3V 90 C G
Output: 15kW
Height: 1385mm
Width: 1025mm
Depth: 580mm
Flue diameter: 200mm
Weight: 280kg
Flue gas: 185°C
Price: 3729 EUR

Kaminasüdamik Echatech 3V 90 G

Kaminasüdamik Echatech 3V 90 G

Kaminasüdamik Echatech 3V 90 G

Echatech 3V 90 G
Output: 15kW
Height: 1385mm
Width: 1025mm
Depth: 580mm
Flue diameter: 200mm
Weight: 280kg
Flue gas: 185°C
Price: 3585 EUR

Kaminasüdamik Echatech EPI 60×74

Kaminasüdamik Echatech EPI 60×74

Kaminasüdamik Echatech EPI 60×74

EPI 60×74
Output: 15kW
Height: 1390mm
Width: 715mm
Depth: 985mm
Flue diameter: 200mm
Weight: 250kg
Flue gas: 240°C
Price: 3828 EUR

Kaminasüdamik Echatech EPI 60×90 C

Kaminasüdamik Echatech EPI 60×90 C

Kaminasüdamik Echatech EPI 60×90

EPI 60×90 C
Output: 18kW
Height: 1395mm
Width: 640mm
Depth: 1150mm
Flue diameter: 200mm
Weight: 280kg
Flue gas: 250°C
Price: 5185 EUR

Kaminasüdamik echatech EPI 60 x 110

Kaminasüdamik echatech EPI 60 x 110

Kaminasüdamik Echatech EPI 60×110

EPI 60×110
Output: 18kW
Height: 1395mm
Width: 715mm
Depth: 1220mm
Flue diameter: 250mm
Weight: 280kg
Flue gas: 225°C
Price: 5809 EUR

Kaminasüdamik Echatech 3V 110 G

Kaminasüdamik Echatech 3V 110 G

Kaminasüdamik Echatech 3V 110 G

Echatech 3V 110 G
Output: 16kW
Height: 1385mm
Width: 1160mm
Depth: 580mm
Flue diameter: 250mm
Weight: 300kg
Flue gas: 205°C
Price: 4245 EUR

Kaminasüdamik Echatech 3V 110 c g

Kaminasüdamik Echatech 3V 110 c g

Kaminasüdamik Echatech 3V 110 C G

Echatech 3V 110 C G
Output: 16kW
Height: 1385mm
Width: 1160mm
Depth: 580mm
Flue diameter: 250mm
Weight: 325kg
Flue gas: 205°C
Price: 4419 EUR

Kaminasüdamik EPI 60×74 C

Kaminasüdamik EPI 60x74 C

Kaminasüdamik EPI 60×74 C

EPI 60×74 C
Output: 15kW
Height: 1390mm
Width: 715mm
Depth: 985mm
Flue diameter: 200mm
Weight: 250kg
Flue gas: 240°C
Price: 3979 EUR

Kaminasüdamik echatech EPI 60×90

Kaminasüdamik echatech EPI 60x90

Kaminasüdamik EPI 60×90

EPI 60×90
Output: 18kW
Height: 1395mm
Width: 640mm
Depth: 1150mm
Flue diameter: 200mm
Weight: 280kg
Flue gas: 250°C
Price: 4990 EUR

Kaminasüdamik EPI 60x110C

Kaminasüdamik EPI 60x110C

Kaminasüdamik EPI 60x110C

EPI 60x110C
Output: 18kW
Height: 1395mm
Width: 715mm
Depth: 1220mm
Flue diameter: 250mm
Weight: 315kg
Flue gas: 225°C
Price: 6159 EUR

Kaminasüdamik Kratki Nadia 14 must sisu

Kaminasüdamik Kratki Nadia 14 must sisu

Kaminasüdamik Nadia 14 must sisu

Nadia 14 must sisu
Output: 14kW
Height: 920,5mm
Width: 979mm
Depth: 445mm
Flue diameter: 200mm
Weight: 177kg
Price: 2495 EUR

Kaminasüdamik kratki-zibi-11-deco-parem

Kaminasüdamik kratki-zibi-11-deco-parem

Kaminasüdamik Zibi 11 Deco parem

Zibi 11 Deco parem
Output: 11kW
Height: 876mm
Width: 776mm
Depth: 440mm
Flue diameter: 180mm
Weight: 161kg
Flue gas: 290°C
Price: 1923 EUR

Kaminasüdamik Kratki Franek 14

Kaminasüdamik Kratki Franek 14

Kaminasüdamik Franek 14

Kaminasüdamik Franek 14
Output:6-17 kw
Height:969 mm
Width:800 mm
Depth:476 mm
Flue diameter :200 mm
Weight: 276kg
Price:2345 EUR

Keskkütte kaminasüdamik AQUATIC WH 70 CP

Keskkütte kaminasüdamik AQUATIC WH 70 CP

Keskkütte kaminasüdamik WH 70 CP

Keskkütte kaminasüdamik
AQUATIC WH 70 CP

Output: 11 kw
Output to water: 7 kW
H/W/D: 1409/627/521mm
Flue diameter: 150 mm
Weight: 230kg
Efficiency: 87%
Kahekordne klaas
Drawing
Price: 4330 EUR

keskkütte kaminasüdamik bef aquatic wh v 70

keskkütte kaminasüdamik bef aquatic wh v 70

Keskküttesüdamik BeF Aquatic WH V 70

Keskkütte kaminasüdamik
AQUATIC WH V 70

Output: 11 kw
Output to water: 8 kW
H/W/D: 1593/901/521mm
Flue diameter: 150 mm
Weight: 352kg
Efficiency: 87%
Kahekordne klaas
Drawing
Price: 4575 EUR

What a fireplace insert is for

A fireplace insert is designed to be built in and is used as an additional heat source in the room where it is installed.

Choosing a fireplace insert

The output of a fireplace insert depends on how well the room is insulated and on the volume to be heated. As a rule of thumb, for a sufficiently insulated room 1 kW of output is enough for 10 m² of floor area with a standard ceiling height (2.5 m). You can always consult our fireplace specialists.

Installing a fireplace insert

Installation of a fireplace insert must comply with applicable legislation, standards, the manufacturer’s instructions and good building practice. The installation should be carried out by a specialist or a qualified company and must comply with national and local regulations.

Chimney flues

Fireplace inserts should be connected to a separate chimney flue in accordance with applicable legislation. It is recommended that:

  • the minimum height of the flue is 3.5–4 m, optimally 5–6 m, measured from the firebox;
  • the flue is leak-tight, has the same diameter along its entire length and rises about 0.5 m above the ridge of the roof so as not to impede the draught;
  • in special situations (wind load zones II and III, local topography) chimney cowls that prevent smoke from blowing back are used.

Attention! If the chimney flue:

  • is smaller than recommended,
  • is located on a building in an unfavourable position (e.g. near high-rise buildings or in a valley),
  • deviates from the vertical and/or has long horizontal sections,

the required negative pressure (draught) may be missing, so flue gases are not drawn out and the fireplace insert smokes. Before installing a fireplace insert, a chimney sweep should assess the draught of the flue and whether the existing flue can be connected to the insert. The draught of the chimney should be 12 ± 2 Pa. A flue with a draught above 12 Pa can cause the insert to overheat and void the warranty. The minimum draught should be 6 ± 1 Pa.

Ventilation and air supply

In rooms where flue gases from fireplace inserts are removed by natural draught, mechanical extract ventilation is not permitted, with the exception of heat recovery units. When a fireplace insert is in use, the room must be supplied with sufficient air: at least 10 m³/h for every 1 kW of the insert’s nominal output. An insufficient air supply causes incomplete combustion, and flue gases containing carbon monoxide and soot may cause smoke. This is dangerous to life and health, reduces the output of the insert and is not grounds for a warranty claim.

Before installation, check that the insert is complete, that all mechanisms work and that the body is sound. The insert should be installed on a non-combustible base at least 0.15 m thick. The floor in front of the door must be protected with a strip of non-combustible material that ensures safe use (at least 0.6 m and no shorter than the length of the open door).

When building the casing of a fireplace insert you must:

  • install the insert on surfaces with sufficient load-bearing capacity;
  • allow air to circulate between the walls of the insert and the casing – leave a gap of at least 6 cm between the fire-resistant insulation of the casing walls and the ribbed surface of the insert;
  • ensure air reaches the insert through an air grille above it (the grille must be designed so that it cannot become blocked);
  • ventilate the insert with a pressure relief grille with an area of 200 cm²; the decompression chamber should be 30–50 cm high, measured from the ceiling;
  • keep a distance of at least 150 cm between the front of the insert and combustible materials;
  • remove all external and safety elements;
  • leave the clearances needed for cleaning the insert and its connector.

After installation, the fireplace insert should be handed over with an acceptance report. Leave at least 6 cm between the insert and the insulation (measured from the ribbed surface to the insulation), and 2–3 cm between the upper part of the facade and the elements of the insert body. Missing these clearances can cause damage and loss of the warranty.

Lighting a fireplace insert for the first time

The first fire should be lit only after the building materials used have dried. Do not make a fierce fire the first time, to avoid a sudden change in temperature. During the first firing a special smell appears – this is the protective coating curing. The smell disappears after a few firings. When lighting, open the primary air supply fully and close it gradually as the fire gets going.

Using a fireplace insert

Safety. Take special care when using a fireplace insert because of the high temperature – there is a risk of burns and fire:

  • use the protective glove supplied by the manufacturer when handling the insert;
  • do not let children near the insert unless supervised by an adult;
  • never dismantle the insert or make any changes to its construction;
  • do not put out the fire in the insert with water;
  • a carbon monoxide detector is recommended in the room where the insert is installed;
  • never leave a burning fire unattended;
  • do not use the insert to dry materials (e.g. clothes), including in its vicinity;
  • never burn fuel in an insert that has not been built in;
  • the door must be closed during normal operation.

If soot ignites in the chimney, notify the nearest fire brigade and a chimney sweep. Until they arrive, fight the fire with a powder extinguisher, directing the jet straight into the chimney flue.

Adjusting the air supply

Combustion can be regulated with the controls provided for this purpose:

  • the position of the handle that opens the damper, which regulates the draught;
  • the position of the slide on the front of the ash pan, which regulates the air supply to the bottom of the firebox.

Firewood for fireplace inserts

Fireplace inserts (depending on the model) burn wood or hardwood briquettes. The heating value of wood is 3.5–3.7 kW/kg when its moisture content is below 20%. Only wood with a moisture content of no more than 20% is suitable – this is reached after about two years of storage. Freshly cut wood has a moisture content of 50–60%. Burning it not only doubles fuel consumption but also causes corrosion of the insert’s parts, rapid soiling of the glass and deposits of soot (creosote) in the insert and flue. Use only the recommended fuel. Do not fill the firebox completely – the optimal amount is about one third of its height. Burning anything other than recommended wood, especially waste and liquid fuels, is prohibited.

Maintenance and cleaning

A fireplace insert must be cleaned regularly, paying particular attention to the flue pipes. A technical inspection by a chimney sweep twice a year is recommended. Chimney flues need to be checked for leaks and swept by a chimney sweep once a year, paying particular attention to whether the flue is clear (it may be blocked by birds’ nests, leaves, etc.). Clean the glass only with products intended for this purpose; regular cleaning prevents permanent stains. Use liquids so that the seals of the insert do not get wet. Remove the ash before the ash pan is completely full, so that it does not block the air supply and the cooling of the grate.