Fireplace inserts

Fireplace inserts2026-11-11T08:13:15+00:00

A fireplace insert is the firebox around which a fireplace of your own design is built. It is the right choice if you want a fireplace built into a wall or in a specific place. A central heating fireplace insert also heats water for radiators in addition to the room. The range includes single-glass, corner and three-sided inserts as well as central heating fireplace inserts. We will help you choose the right output and chimney – visit our showroom in Tallinn or Pärnu or ask for advice.

Kaminasüdamik Lucy 14 Tunnel

Kaminasüdamik Lucy 14 Tunnel

Kaminasüdamik Lucy 14 Tunnel

Lucy 14 Tunnel
Output: 14kW
Height: 1280mm
Width: 804mm
Depth: 420mm
Flue diameter: 200mm
Website
Price: 2822 EUR
Black firebox lining: +100 EUR

Kaminasüdamik Lucy Slim 8 parem

Kaminasüdamik Lucy Slim 8 parem

Kaminasüdamik Lucy Slim 8 parem

Output: 3-10 kW
Height: 1282mm
Width: 781mm
Depth: 415mm
Weight:171kg
Flue diameter: 160mm
Price: 2105 EUR
Black firebox lining: +100 EUR

Kaminasüdamik Lucy Slim 8 vasak

Kaminasüdamik Lucy Slim 8 vasak

Kaminasüdamik Lucy Slim 8 vasak

Output: 3-10 kW
Height: 1282mm
Width: 781mm
Depth: 415mm
Weight:171kg
Flue diameter: 160mm
Price: 2105 EUR
Black firebox lining: +100 EUR

Kahepoolne kaminasüdamik Ardente DUO 90×41.DSS

Kahepoolne kaminasüdamik Ardente DUO 90x41.DSS

Kahepoolne kaminasüdamik Ardente DUO 90×41.DSS

Output: 18 kw
Height: 1554 mm
Width: 1007 mm
Depth: 568 mm
Glass: 420×903 mm
Flue diameter: 200 mm
Price: 3515 EUR
Black firebox lining: +340 EUR
Heat storage kit: 330 EUR

Kaminasüdamik Nordflam Lucio

Kaminasüdamik Nordflam Lucio

Kaminasüdamik Lucio

Kaminasüdamik Lucio
Output: 16 kw
Height: 830/520 mm
Width: 690 mm
Depth: 438+50 mm
Weight: 130 kg
Flue diameter: 180 mm
Price: 665 EUR

Keskkütte kaminasüdamik W17CO

Keskkütte kaminasüdamik W17COKeskkütte südamik W17CO
Output: 11,9 kW, vette 7,8 kW
Water tank volume: 31 l
Height: 800 mm
Width: 665 mm
Depth: 515 mm
Flue diameter: 200 mm
Weight: 120 kg
Price: 1319 EUR
Price: 1098 EUR

Kaminasüdamik Volcano FDTh

Volcano FDTh

Kaminasüdamik Volcano FDTh

Kaminasüdamik Volcano FDTh
Output: 4,5-14 kW
Height: 1334 mm
Width: 795 mm
Depth: 591 mm
Flue diameter: 200 mm
Weight: 245 kg
Price: 4115 EUR

Keskkütte kaminasüdamik MBA/PW/17/L/BS/W

Keskkütte kaminasüdamik MBA/PW/17/L/BS/W

Keskkütte kaminasüdamik MBA/PW/17/L/BS/W

MBA/PW/17/L/BS/W
Output: 9-19,5 kW
Water tank volume: 47 l
Height: 1460 mm
Width: 910 mm
Depth: 575 mm
Flue diameter: 200 mm
Weight: 293 kg
Price: 3364 EUR

Keskkütte kaminasüdamik MBA/PW/17/P/BS/W

Keskkütte kaminasüdamik MBA/PW/17/P/BS/W

Keskkütte kaminasüdamik MBA/PW/17/P/BS/W

Output: 9-19,5 kW
Water tank volume: 47 l
Height: 1460 mm
Width: 910 mm
Depth: 575 mm
Flue diameter: 200 mm
Weight: 293 kg
Price: 3364 EUR

Keskkütte südamik Maja PW 12 Deco

Keskkütte südamik Maja PW 12 Deco

Keskkütte kaminasüdamik Maja PW 12 Deco

Maja PW 12 Deco
Output: 3,5-10 kW
Water tank volume: 18 l
H/W/D: 677/635/384mm
Flue diameter: 180 mm
Weight: 110 kg
Price: 1529 EUR

 

Malmist kaminasdamik Amelia

Malmist kaminasdamik Amelia

Kaminasüdamik Amelia 21kW

Kaminasüdamik Amelia
Output: 21 KW
Height: 902mm
Width: 750 mm
Depth: 444 mm
Flue diameter: Ø 200 mm
Weight: 181 kg
Glass dimensions:613×461
Price: 1499 EUR

Kaminasüdamik Nordflam Alber

Kaminasüdamik Nordflam Alber

Kaminasüdamik Alber

Kaminasüdamik Alber
Output: 14 kw
Height: 520/697 mm
Width: 690 mm
Depth: 438+50 mm
Weight: 116 kg
Flue diameter: 180 mm
Price: 545 EUR

Kaminasüdamik Panadero Hogar HS

Kaminasüdamik Panadero Hogar HS

Kaminasüdamik Panadero Hogar HS

Output: 7,1kW
Height: 594mm
Width: 617mm
Depth: 396mm
Flue diameter: 150mm
Weight: 110kg
Price: 1309 EUR

Kaminasüdamik Panadero Hogar HB

Kaminasüdamik Panadero Hogar HB

Kaminasüdamik Panadero Hogar HB

Output: 9,8kW
Height: 612mm
Width: 756mm
Depth: 433mm
Flue diameter: 150mm
Weight: 130kg
Price: 1843 EUR

Kaminasüdamik Panadero Hogar 101-S

Kaminasüdamik Panadero Hogar 101-S

Kaminasüdamik Panadero Hogar 101-S

Output: 9kW
Height: 627mm
Width: 1120mm
Depth: 470mm
Flue diameter: 150mm
Weight: 120kg
Price: 1775 EUR

What a fireplace insert is for

A fireplace insert is designed to be built in and is used as an additional heat source in the room where it is installed.

Choosing a fireplace insert

The output of a fireplace insert depends on how well the room is insulated and on the volume to be heated. As a rule of thumb, for a sufficiently insulated room 1 kW of output is enough for 10 m² of floor area with a standard ceiling height (2.5 m). You can always consult our fireplace specialists.

Installing a fireplace insert

Installation of a fireplace insert must comply with applicable legislation, standards, the manufacturer’s instructions and good building practice. The installation should be carried out by a specialist or a qualified company and must comply with national and local regulations.

Chimney flues

Fireplace inserts should be connected to a separate chimney flue in accordance with applicable legislation. It is recommended that:

  • the minimum height of the flue is 3.5–4 m, optimally 5–6 m, measured from the firebox;
  • the flue is leak-tight, has the same diameter along its entire length and rises about 0.5 m above the ridge of the roof so as not to impede the draught;
  • in special situations (wind load zones II and III, local topography) chimney cowls that prevent smoke from blowing back are used.

Attention! If the chimney flue:

  • is smaller than recommended,
  • is located on a building in an unfavourable position (e.g. near high-rise buildings or in a valley),
  • deviates from the vertical and/or has long horizontal sections,

the required negative pressure (draught) may be missing, so flue gases are not drawn out and the fireplace insert smokes. Before installing a fireplace insert, a chimney sweep should assess the draught of the flue and whether the existing flue can be connected to the insert. The draught of the chimney should be 12 ± 2 Pa. A flue with a draught above 12 Pa can cause the insert to overheat and void the warranty. The minimum draught should be 6 ± 1 Pa.

Ventilation and air supply

In rooms where flue gases from fireplace inserts are removed by natural draught, mechanical extract ventilation is not permitted, with the exception of heat recovery units. When a fireplace insert is in use, the room must be supplied with sufficient air: at least 10 m³/h for every 1 kW of the insert’s nominal output. An insufficient air supply causes incomplete combustion, and flue gases containing carbon monoxide and soot may cause smoke. This is dangerous to life and health, reduces the output of the insert and is not grounds for a warranty claim.

Before installation, check that the insert is complete, that all mechanisms work and that the body is sound. The insert should be installed on a non-combustible base at least 0.15 m thick. The floor in front of the door must be protected with a strip of non-combustible material that ensures safe use (at least 0.6 m and no shorter than the length of the open door).

When building the casing of a fireplace insert you must:

  • install the insert on surfaces with sufficient load-bearing capacity;
  • allow air to circulate between the walls of the insert and the casing – leave a gap of at least 6 cm between the fire-resistant insulation of the casing walls and the ribbed surface of the insert;
  • ensure air reaches the insert through an air grille above it (the grille must be designed so that it cannot become blocked);
  • ventilate the insert with a pressure relief grille with an area of 200 cm²; the decompression chamber should be 30–50 cm high, measured from the ceiling;
  • keep a distance of at least 150 cm between the front of the insert and combustible materials;
  • remove all external and safety elements;
  • leave the clearances needed for cleaning the insert and its connector.

After installation, the fireplace insert should be handed over with an acceptance report. Leave at least 6 cm between the insert and the insulation (measured from the ribbed surface to the insulation), and 2–3 cm between the upper part of the facade and the elements of the insert body. Missing these clearances can cause damage and loss of the warranty.

Lighting a fireplace insert for the first time

The first fire should be lit only after the building materials used have dried. Do not make a fierce fire the first time, to avoid a sudden change in temperature. During the first firing a special smell appears – this is the protective coating curing. The smell disappears after a few firings. When lighting, open the primary air supply fully and close it gradually as the fire gets going.

Using a fireplace insert

Safety. Take special care when using a fireplace insert because of the high temperature – there is a risk of burns and fire:

  • use the protective glove supplied by the manufacturer when handling the insert;
  • do not let children near the insert unless supervised by an adult;
  • never dismantle the insert or make any changes to its construction;
  • do not put out the fire in the insert with water;
  • a carbon monoxide detector is recommended in the room where the insert is installed;
  • never leave a burning fire unattended;
  • do not use the insert to dry materials (e.g. clothes), including in its vicinity;
  • never burn fuel in an insert that has not been built in;
  • the door must be closed during normal operation.

If soot ignites in the chimney, notify the nearest fire brigade and a chimney sweep. Until they arrive, fight the fire with a powder extinguisher, directing the jet straight into the chimney flue.

Adjusting the air supply

Combustion can be regulated with the controls provided for this purpose:

  • the position of the handle that opens the damper, which regulates the draught;
  • the position of the slide on the front of the ash pan, which regulates the air supply to the bottom of the firebox.

Firewood for fireplace inserts

Fireplace inserts (depending on the model) burn wood or hardwood briquettes. The heating value of wood is 3.5–3.7 kW/kg when its moisture content is below 20%. Only wood with a moisture content of no more than 20% is suitable – this is reached after about two years of storage. Freshly cut wood has a moisture content of 50–60%. Burning it not only doubles fuel consumption but also causes corrosion of the insert’s parts, rapid soiling of the glass and deposits of soot (creosote) in the insert and flue. Use only the recommended fuel. Do not fill the firebox completely – the optimal amount is about one third of its height. Burning anything other than recommended wood, especially waste and liquid fuels, is prohibited.

Maintenance and cleaning

A fireplace insert must be cleaned regularly, paying particular attention to the flue pipes. A technical inspection by a chimney sweep twice a year is recommended. Chimney flues need to be checked for leaks and swept by a chimney sweep once a year, paying particular attention to whether the flue is clear (it may be blocked by birds’ nests, leaves, etc.). Clean the glass only with products intended for this purpose; regular cleaning prevents permanent stains. Use liquids so that the seals of the insert do not get wet. Remove the ash before the ash pan is completely full, so that it does not block the air supply and the cooling of the grate.

Go to Top