Fireplace inserts

Fireplace inserts2026-11-11T08:13:15+00:00

A fireplace insert is the firebox around which a fireplace of your own design is built. It is the right choice if you want a fireplace built into a wall or in a specific place. A central heating fireplace insert also heats water for radiators in addition to the room. The range includes single-glass, corner and three-sided inserts as well as central heating fireplace inserts. We will help you choose the right output and chimney – visit our showroom in Tallinn or Pärnu or ask for advice.

Kaminasüdamik Thermorossi Skyline 800

Kaminasüdamik Thermorossi Skyline 800

Kaminasüdamik Thermorossi Skyline 800

Output: 6,8-12,5 kW
Height: 540 mm
Width: 785 mm
Depth: 450 mm
Flue diameter: 130 mm
Air intake pipe: 60 mm
Warm air ducts: 2 x 100 mm
Flue connection: Top
Weight: 152 kg
Technical drawing
Price: 2650 EUR

Pelletiga kaminasüdamik Boxline 8-10

Pelletiga kaminasüdamik Boxline 8-10

Pelletiga kaminasüdamik Boxline 8-10

Boxline 8: 2,9-8,6 kW
Boxline 10: 2,9-10,1 kW
Consumption:0,6-1,6 (1,9) kg/h
Height: 770 mm
Width: 830 mm
Depth: 642 mm
Pellet hopper capacity: 14 kg
Weight: 130 kg
Flue: 80mm
Technical drawing
Boxline 8: 4785 EUR
Boxline 10: 4890 EUR
Pellet loading opening: +195 EUR
Decorative frame: +229 EUR

Pelletiga kaminasüdamik Sienna 7-10

Pelletiga kaminasüdamik Sienna 7-10

Pelletiga kaminasüdamik Sienna 7-10

Pelletiga kaminasüdamik Sienna 7-10

Sienna 7: 2,2-7,5 kW
Sienna 10: 2,2-10,3 kW
Consumption:0,6-1,9 (2,2) kg/h
Height: 1007 mm
Width: 694 mm
Depth: 554 mm
Pellet hopper capacity: 27 kg
Weight: 175 kg
Flue: 80mm
Technical drawing
Sienna 7: 4875 EUR
Sienna 10: 4987 EUR
Pellet loading opening: +195 EUR
Decorative frame: +229 EUR

Soojustagastusega ventilaator VT-100

Soojustagastusega ventilaator VT-100

Soojustagastusega ventilaator VT-100

Airflow: up to 50 m³/h
Air duct diameter: 100 mm
Operating temperature: -20 °C up to +50 °C
Weight: only 2 kg
Kuni 90% efektiivsus – keraamiline soojusvaheti tagab tõhusa energia taaskasutuse.
Vaikne töö – müratase alates vaid 13 dB-st (öörežiim).
Energiatõhusus – energiaklass A ja EC-mootor vähendavad energiatarbimist.
Lihtne paigaldus – teleskoopkanal kohandub seina paksusega (270–490 mm).
4 töörežiimi – sh tsükliline ja öörežiim täieliku mugavuse tagamiseks.
Kaugjuhtimispult
Price: 277 EUR

Kaminasüdamik Hitze 68×43.G

Kaminasüdamik Hitze 68x43.G

Kaminasüdamik HST 68×43.G

Output: 6,5-17kw
Height: 1313mm
Width: 814mm
Depth: 514mm
Weight: 205kg
Flue diameter: 160mm
Technical drawing 
Price: 2499 EUR
Black firebox lining: +330 EUR
Heat storage kit: 350 EUR

Kaminasüdamik Hitze HST68x43.S

Kaminasüdamik Hitze HST68x43.S

Kaminasüdamik HST68x43.S

Output: 4,5-12kW
Height: 1313mm
Width: 791mm
Depth: 419mm
Weight: 180kg
Flue diameter: 160mm
Technical drawing
Price: 1949 EUR
Black firebox lining: +310 EUR
Heat storage kit: 580 EUR
Topeltklaas: +140 EUR

Kaminasüdamik EvaCalor Carlo

Kaminasüdamik EvaCalor Carlo

Kaminasüdamik EvaCalor Carlo

Output: 12,5-14,5kW
Height: 1651mm
Width: 902mm
Depth: 529mm
Flue diameter: 180mm
Air intake pipe: 120mm
Warm air ducts: 4 x 120mm
Flue connection: Top
Weight: 260kg
Technical drawing
Price: 3498 EUR

Kaminasüdamik Thermorossi Skyline 490

Kaminasüdamik Thermorossi Skyline 490

Kaminasüdamik Thermorossi Skyline 490

Output: 7,9-10,9 kW
Height: 490 mm
Width: 690 mm
Depth: 450 mm
Flue diameter: 130 mm
Air intake pipe: 60 mm
Warm air ducts: 2 x 100 mm
Flue connection: Top
Weight: 131 kg
Technical drawing
Price: 2200 EUR
Airbox fan: +280 EUR

Kaminasüdamik Thermorossi Skyline 540

Kaminasüdamik Thermorossi Skyline 540

Kaminasüdamik Thermorossi Skyline 540

Output: 5,7-12,5kW
Height: 540mm
Width: 690mm
Depth: 483mm
Flue diameter: 130mm
Air intake pipe: 60mm
Warm air ducts: 2 x 100mm
Flue connection: Top
Weight: 131kg
Technical drawing
Price: 2300 EUR
Airbox fan: +280 EUR

Kaminasüdamik Thermorossi Panorama Corner

Kaminasüdamik Thermorossi Panorama Corner

Kaminasüdamik Thermorossi Panorama Corner

Output: 5,7-12,5kW
Height: 540mm
Width: 690mm
Depth: 485mm
Flue diameter: 130mm
Air intake pipe: 60mm
Warm air ducts: 2 x 100mm
Flue connection: Top
Weight: 131kg
Technical drawing
Price: 2700 EUR
Airbox fan: +280 EUR

Kaminasüdamik Thermorossi Panorama

Kaminasüdamik Thermorossi Panorama

Kaminasüdamik Thermorossi Panorama

Output: 5,7-12,5 kW
Height: 540 mm
Width: 690 mm
Depth: 485 mm
Flue diameter: 130 mm
Air intake pipe: 60 mm
Warm air ducts: 2 x 100 mm
Flue connection: Top
Weight: 131 kg
Technical drawing
Price: 2700 EUR
Airbox fan: +280 EUR

Keskkütte kaminasüdamik Hergom H-02/22

Keskkütte kaminasüdamik Hergom H-02/22

Keskkütte kaminasüdamik Hergom H-02/22

Output: 15-22 kW
Output to water: 6,4-16 kW
Võimsus õhku: 9 kW
Log length: 500 mm
Height: 1172 mm
Width: 790 mm
Depth: 527 mm
Flue diameter: 200 mm
Weight: 230 kg
Technical data
Price: 3110 EUR

Keskkütte kaminasüdamik Hergom DERO

Keskkütte kaminasüdamik Hergom DERO

Keskkütte kaminasüdamik Hergom DERO

Output: 25-35kW
Output to water: 21kW
Võimsus õhku: 13,9kW
Log length: 550mm
Height: 1268mm
Width: 939mm
Depth: 712mm
Flue diameter: 200mm
Weight: 271kg
Technical data
Price: 4655 EUR

Kaminasüdamik HWAM I 40/55c

Kaminasüdamik HWAM I 40/55c

Kaminasüdamik HWAM I 40/55c

Output: 6,4 kW
Height: 543 mm
Width: 744 mm
Depth: 396 mm
Flue diameter: 150 mm
Flue connection: Top/rear
Weight: 99 kg
Technical drawing
Price: 1830 EUR
Price: 2455 EUR (SmartControl)

Kaminasüdamik HWAM I 40/55m

Kaminasüdamik HWAM I 40/55m

Kaminasüdamik HWAM I 40/55m

Output: 6,4 kW
Height: 543 mm
Width: 744 mm
Depth: 396 mm
Flue diameter: 150 mm
Flue connection: Top/rear
Weight: 97 kg
Technical drawing
Price: 1945 EUR
Price: 2566 EUR (SmartControl)

Kaminasüdamik Hergom H-03/70S

Kaminasüdamik Hergom H-03/70S

Kaminasüdamik Hergom H-03/70S

Output: 11-15kW
Height: 519-677mm
Width: 700mm
Depth: 429-476mm
Flue diameter: 150mm
Log length: 500mm
Weight: 117kg
Technical drawing
Price: 1332 EUR
Välisõhu ühendus: 104 EUR

What a fireplace insert is for

A fireplace insert is designed to be built in and is used as an additional heat source in the room where it is installed.

Choosing a fireplace insert

The output of a fireplace insert depends on how well the room is insulated and on the volume to be heated. As a rule of thumb, for a sufficiently insulated room 1 kW of output is enough for 10 m² of floor area with a standard ceiling height (2.5 m). You can always consult our fireplace specialists.

Installing a fireplace insert

Installation of a fireplace insert must comply with applicable legislation, standards, the manufacturer’s instructions and good building practice. The installation should be carried out by a specialist or a qualified company and must comply with national and local regulations.

Chimney flues

Fireplace inserts should be connected to a separate chimney flue in accordance with applicable legislation. It is recommended that:

  • the minimum height of the flue is 3.5–4 m, optimally 5–6 m, measured from the firebox;
  • the flue is leak-tight, has the same diameter along its entire length and rises about 0.5 m above the ridge of the roof so as not to impede the draught;
  • in special situations (wind load zones II and III, local topography) chimney cowls that prevent smoke from blowing back are used.

Attention! If the chimney flue:

  • is smaller than recommended,
  • is located on a building in an unfavourable position (e.g. near high-rise buildings or in a valley),
  • deviates from the vertical and/or has long horizontal sections,

the required negative pressure (draught) may be missing, so flue gases are not drawn out and the fireplace insert smokes. Before installing a fireplace insert, a chimney sweep should assess the draught of the flue and whether the existing flue can be connected to the insert. The draught of the chimney should be 12 ± 2 Pa. A flue with a draught above 12 Pa can cause the insert to overheat and void the warranty. The minimum draught should be 6 ± 1 Pa.

Ventilation and air supply

In rooms where flue gases from fireplace inserts are removed by natural draught, mechanical extract ventilation is not permitted, with the exception of heat recovery units. When a fireplace insert is in use, the room must be supplied with sufficient air: at least 10 m³/h for every 1 kW of the insert’s nominal output. An insufficient air supply causes incomplete combustion, and flue gases containing carbon monoxide and soot may cause smoke. This is dangerous to life and health, reduces the output of the insert and is not grounds for a warranty claim.

Before installation, check that the insert is complete, that all mechanisms work and that the body is sound. The insert should be installed on a non-combustible base at least 0.15 m thick. The floor in front of the door must be protected with a strip of non-combustible material that ensures safe use (at least 0.6 m and no shorter than the length of the open door).

When building the casing of a fireplace insert you must:

  • install the insert on surfaces with sufficient load-bearing capacity;
  • allow air to circulate between the walls of the insert and the casing – leave a gap of at least 6 cm between the fire-resistant insulation of the casing walls and the ribbed surface of the insert;
  • ensure air reaches the insert through an air grille above it (the grille must be designed so that it cannot become blocked);
  • ventilate the insert with a pressure relief grille with an area of 200 cm²; the decompression chamber should be 30–50 cm high, measured from the ceiling;
  • keep a distance of at least 150 cm between the front of the insert and combustible materials;
  • remove all external and safety elements;
  • leave the clearances needed for cleaning the insert and its connector.

After installation, the fireplace insert should be handed over with an acceptance report. Leave at least 6 cm between the insert and the insulation (measured from the ribbed surface to the insulation), and 2–3 cm between the upper part of the facade and the elements of the insert body. Missing these clearances can cause damage and loss of the warranty.

Lighting a fireplace insert for the first time

The first fire should be lit only after the building materials used have dried. Do not make a fierce fire the first time, to avoid a sudden change in temperature. During the first firing a special smell appears – this is the protective coating curing. The smell disappears after a few firings. When lighting, open the primary air supply fully and close it gradually as the fire gets going.

Using a fireplace insert

Safety. Take special care when using a fireplace insert because of the high temperature – there is a risk of burns and fire:

  • use the protective glove supplied by the manufacturer when handling the insert;
  • do not let children near the insert unless supervised by an adult;
  • never dismantle the insert or make any changes to its construction;
  • do not put out the fire in the insert with water;
  • a carbon monoxide detector is recommended in the room where the insert is installed;
  • never leave a burning fire unattended;
  • do not use the insert to dry materials (e.g. clothes), including in its vicinity;
  • never burn fuel in an insert that has not been built in;
  • the door must be closed during normal operation.

If soot ignites in the chimney, notify the nearest fire brigade and a chimney sweep. Until they arrive, fight the fire with a powder extinguisher, directing the jet straight into the chimney flue.

Adjusting the air supply

Combustion can be regulated with the controls provided for this purpose:

  • the position of the handle that opens the damper, which regulates the draught;
  • the position of the slide on the front of the ash pan, which regulates the air supply to the bottom of the firebox.

Firewood for fireplace inserts

Fireplace inserts (depending on the model) burn wood or hardwood briquettes. The heating value of wood is 3.5–3.7 kW/kg when its moisture content is below 20%. Only wood with a moisture content of no more than 20% is suitable – this is reached after about two years of storage. Freshly cut wood has a moisture content of 50–60%. Burning it not only doubles fuel consumption but also causes corrosion of the insert’s parts, rapid soiling of the glass and deposits of soot (creosote) in the insert and flue. Use only the recommended fuel. Do not fill the firebox completely – the optimal amount is about one third of its height. Burning anything other than recommended wood, especially waste and liquid fuels, is prohibited.

Maintenance and cleaning

A fireplace insert must be cleaned regularly, paying particular attention to the flue pipes. A technical inspection by a chimney sweep twice a year is recommended. Chimney flues need to be checked for leaks and swept by a chimney sweep once a year, paying particular attention to whether the flue is clear (it may be blocked by birds’ nests, leaves, etc.). Clean the glass only with products intended for this purpose; regular cleaning prevents permanent stains. Use liquids so that the seals of the insert do not get wet. Remove the ash before the ash pan is completely full, so that it does not block the air supply and the cooling of the grate.

Go to Top