A fireplace insert is the firebox around which a fireplace of your own design is built. It is the right choice if you want a fireplace built into a wall or in a specific place. A central heating fireplace insert also heats water for radiators in addition to the room. The range includes single-glass, corner and three-sided inserts as well as central heating fireplace inserts. We will help you choose the right output and chimney – visit our showroom in Tallinn or Pärnu or ask for advice.

Kaminasüdamik Hergom HGB-70

Kaminasüdamik Hergom HGB-70

Kaminasüdamik Hergom HGB-70

Output: 11-15kW
Height: 519-677mm
Width: 693mm
Depth: 429-476mm
Flue diameter: 150mm
Log length: 500mm
Weight: 117kg
Technical drawing
Price: 1118 EUR
Välisõhu adapter: 104 EUR

Kaminasüdamik Hergom C3/70

Kaminasüdamik Hergom C-3/70

Kaminasüdamik Hergom C-3/70

Output: 8-13kW
Height: 585mm
Width: 778mm
Depth: 514mm
Flue diameter: 150mm
Sooja õhu kanal 2x120mm
Log length: 500mm
Weight: 120kg
Technical drawing
Price: 1853 EUR
Decorative frame: 171 EUR
External air kit: 59 EUR

Kaminasüdamik Hergom C-3/80

Kaminasüdamik Hergom C-3/80

Kaminasüdamik Hergom C-3/80

Output: 8-14kW
Height: 560mm
Width: 877mm
Depth: 514mm
Flue diameter: 175mm
Sooja õhu kanal 2x120mm
Log length: 600mm
Weight: 140kg
Technical drawing
Price: 2017 EUR
Decorative frame: 190 EUR
External air kit: 59 EUR

Kaminasüdamik Hergom C16/70

Kaminasudamik Hergom C-16/70

Kaminasudamik Hergom C-16/70

Output: 8-13kW
Height: 585mm
Width: 778mm
Depth: 514mm
Flue diameter: 150mm
Sooja õhu kanal 2x120mm
Log length: 500mm
Weight: 120kg
Technical drawing
Price: 1984 EUR
Decorative frame: 171 EUR
External air kit: 59 EUR

Kaminasudamik Hergom C-16/80

Kaminasudamik Hergom C-16/80

Kaminasudamik Hergom C-16/80

Output: 8-14kW
Height: 583mm
Width: 877mm
Depth: 508mm
Flue diameter: 175mm
Sooja õhu kanal 2x120mm
Log length: 600mm
Weight: 140kg
Technical drawing
Price: 2179 EUR
Decorative frame: 190 EUR
External air kit: 59 EUR

Kaminasüdamik Hergom SERE 100

Kaminasüdamik Hergom SERE 100

Kaminasüdamik SERE 100

Output: 12-18 kW
Height: 609 mm
Width: 1015 mm
Depth: 500 mm
Flue diameter: 200 mm
Õhuvõtt: 80 mm
Sooja õhu kanal 2x120mm
Weight: 134 kg
Technical drawing
Price: 2877 EUR
Decorative frame: 131-150 EUR

Praeahjuga kaminasüdamik Carbel Atlas

Praeahjuga kaminasüdamik Carbel Atlas

Praeahjuga kaminasüdamik Carbel Atlas

Output: 6-12 kw
Height: 1130 mm
Width: 700 mm
Depth: 430 mm
Flue diameter: 180 mm
Weight: 243 kg
Efficiency: 84%
Drawing
Price: 1909 EUR
Decorative frame: 138 EUR
Fan: 175 EUR

 

Praeahjuga kaminasüdamik Bake 70

Praeahjuga kaminasüdamik Bake 70

Praeahjuga kaminasüdamik Bake 70

Output: 7,3kW
Height: 1100mm
Width: 698mm
Depth: 453mm
Flue diameter: 150mm
Weight: 243 g
Efficiency: 78%
Price: 3074 EUR
Black decorative frame: 150 EUR
Stainless steel decorative frame: 218 EUR
Stainless steel handle 2x: 160 EUR
Support legs: 160 EUR

Praeahjuga kaminasüdamik Bake 70 sahtliga

Praeahjuga kaminasüdamik Bake 70 sahtliga

Praeahjuga kaminasüdamik Bake 70 sahtliga

Output: 7,3 kw
Height: 1280 mm
Width: 698 mm
Depth: 453 mm
Flue diameter: 150 mm
Weight: 217 kg
Efficiency: 78%
Price: 3316 EUR
Black decorative frame: 150 EUR
Stainless steel decorative frame: 216 EUR
Stainless steel handle 2x: 160 EUR

Kaminasüdamik CRYSTAL FLAME 80 FRONTAL LATERAL R/L

Kaminasüdamik CRYSTAL FLAME 80 FRONTAL LATERAL R/L

Kaminasüdamik CRYSTAL FLAME 80 FRONTAL LATERAL R/L

Output: 10,6kw
Height: 555mm
Width: 757mm
Depth: 468mm
Flue diameter: 175mm
Weight: 146kg
Efficiency: 82%
Price: 2860 EUR
Black decorative frame: 165 EUR
Support legs: 189 EUR

Kaminasüdamik CRYSTAL FLAME 80 FRONTAL LATERAL 3L

Kaminasüdamik CRYSTAL FLAME 80 FRONTAL LATERAL 3L

Kaminasüdamik CRYSTAL FLAME 80 FRONTAL LATERAL 3L

Output: 10,6 kw
Height: 555 mm
Width: 733 mm
Depth: 464 mm
Flue diameter: 175 mm
Weight: 142 kg
Efficiency: 82%
Price: 2989 EUR
Black decorative frame: 165 EUR
Support legs: 189 EUR

Kaminasüdamik Crystal Flame 80 Vision L

Kaminasüdamik Crystal Flame 80 Vision L

Kaminasüdamik Crystal Flame 80 Vision L

Output: 10,6kW
Height: 555mm
Width: 757mm
Depth: 468mm
Flue diameter: 175mm
Weight: 140kg
Efficiency: 82%
Price: 3360 EUR
Black decorative frame: 190 EUR
Support legs: 189 EUR

Kaminasüdamik Crystal 80 Vision 360

Kaminasüdamik Crystal 80 Vision 360

Kaminasüdamik Crystal 80 Vision 360

Output: 10,6kW
Height: 555mm
Width: 734mm
Depth: 468mm
Flue diameter: 175mm
Weight: 133kg
Efficiency: 82%
Price: 3239 EUR
Black decorative frame: 220 EUR
Support legs: 189 EUR

Kaminasüdamik CRYSTAL FLAME 70

Kaminasüdamik CRYSTAL FLAME 70

Kaminasüdamik CRYSTAL FLAME 70

Output: 7,3kW
Height: 555mm
Width: 692mm
Depth: 460mm
Flue diameter: 150mm
Weight: 130kg
Efficiency: 78 %
Price: 2068 EUR
Black decorative frame: 135 EUR
Stainless steel decorative frame: 210 EUR
Stainless steel handle: 80 EUR
Support legs: 160 EUR

Kaminasüdamik CRYSTAL FLAME 80

Kaminasüdamik CRYSTAL FLAME 80

Kaminasüdamik CRYSTAL FLAME 80

Output: 10,6kW
Height: 555mm
Width: 781mm
Depth: 460mm
Flue diameter: 175mm
Weight: 143kg
Efficiency: 82%
Price: 2300 EUR
Black decorative frame: 140 EUR
Stainless steel decorative frame: 230 EUR
Stainless steel handle: 80 EUR
Support legs: 160 EUR

Kaminasüdamik Crystal Flame 100

Kaminasüdamik Crystal Flame 100

Kaminasüdamik Crystal Flame 100

Output: 11,6kW
Height: 555mm
Width: 980mm
Depth: 460mm
Flue diameter: 175mm
Weight: 168kg
Efficiency: 82%
Price: 2709 EUR
Black decorative frame: 150 EUR
Stainless steel decorative frame: 270 EUR
Stainless steel handle: 90 EUR
Support legs: 160 EUR

Kahepoolne kaminasüdamik CRYSTAL FLAME 70 DF

Kahepoolne kaminasüdamik CRYSTAL FLAME 70 DF

Kahepoolne kaminasüdamik CRYSTAL FLAME 70 DF

Output: 7,3kW
Height: 555mm
Width: 692mm
Depth: 468mm
Flue diameter: 150mm
Weight: 128kg
Efficiency: 78%
Price: 2539 EUR
Black decorative frame: 135 EUR
Stainless steel decorative frame: 210 EUR
Stainless steel handle: 80 EUR
Support legs: 160 EUR

Kakepoolne kaminasüdamik CRYSTAL FLAME 80 DF

Kahepoolne kaminasüdamik CRYSTAL FLAME 80 DF

Kahepoolne kaminasüdamik CRYSTAL FLAME 80 DF

Output: 10,6kW
Height: 555mm
Width: 781mm
Depth: 468mm
Flue diameter: 175mm
Weight: 138kg
Efficiency: 82%
Price: 2715 EUR
Black decorative frame: 140 EUR
Stainless steel decorative frame: 230 EUR
Stainless steel handle: 80 EUR
Support legs: 160 EUR

Kahepoolne kaminasüdamik CRYSTAL FLAME 100 DF

Kahepoolne kaminasüdamik CRYSTAL FLAME 100 DF

Kahepoolne kaminasüdamik CRYSTAL FLAME 100 DF

Output: 11,6kW
Height: 555mm
Width: 980mm
Depth: 468mm
Flue diameter: 175mm
Weight: 160kg
Efficiency: 82%
Price: 3300 EUR
Black decorative frame: 150 EUR
Stainless steel decorative frame: 270 EUR
Stainless steel handle: 90 EUR
Support legs: 160 EUR

Kaminasüdamik Kratki Regnor 800/400

Kaminasüdamik Kratki Regnor 800/400

Kaminasüdamik Regnor 800/400

Output: 9kW
Height: 1470/464(klaas)mm
Width: 654/594mm
Depth: 632/357mm
Flue diameter: 200mm
Weight: 234kg
Price:4580 EUR

Kaminasüdamik Kratki NBC 9 must sisu

Kaminasüdamik Kratki NBC 9 must sisu

Kaminasüdamik Kratki NBC 9 must sisu

Output: 9 kw
Height: 1470/464(klaas) mm
Width: 654/594 mm
Depth: 632/357 mm
Flue diameter: 200 mm
Weight: 234 kg
Price:3945 EUR

What a fireplace insert is for

A fireplace insert is designed to be built in and is used as an additional heat source in the room where it is installed.

Choosing a fireplace insert

The output of a fireplace insert depends on how well the room is insulated and on the volume to be heated. As a rule of thumb, for a sufficiently insulated room 1 kW of output is enough for 10 m² of floor area with a standard ceiling height (2.5 m). You can always consult our fireplace specialists.

Installing a fireplace insert

Installation of a fireplace insert must comply with applicable legislation, standards, the manufacturer’s instructions and good building practice. The installation should be carried out by a specialist or a qualified company and must comply with national and local regulations.

Chimney flues

Fireplace inserts should be connected to a separate chimney flue in accordance with applicable legislation. It is recommended that:

  • the minimum height of the flue is 3.5–4 m, optimally 5–6 m, measured from the firebox;
  • the flue is leak-tight, has the same diameter along its entire length and rises about 0.5 m above the ridge of the roof so as not to impede the draught;
  • in special situations (wind load zones II and III, local topography) chimney cowls that prevent smoke from blowing back are used.

Attention! If the chimney flue:

  • is smaller than recommended,
  • is located on a building in an unfavourable position (e.g. near high-rise buildings or in a valley),
  • deviates from the vertical and/or has long horizontal sections,

the required negative pressure (draught) may be missing, so flue gases are not drawn out and the fireplace insert smokes. Before installing a fireplace insert, a chimney sweep should assess the draught of the flue and whether the existing flue can be connected to the insert. The draught of the chimney should be 12 ± 2 Pa. A flue with a draught above 12 Pa can cause the insert to overheat and void the warranty. The minimum draught should be 6 ± 1 Pa.

Ventilation and air supply

In rooms where flue gases from fireplace inserts are removed by natural draught, mechanical extract ventilation is not permitted, with the exception of heat recovery units. When a fireplace insert is in use, the room must be supplied with sufficient air: at least 10 m³/h for every 1 kW of the insert’s nominal output. An insufficient air supply causes incomplete combustion, and flue gases containing carbon monoxide and soot may cause smoke. This is dangerous to life and health, reduces the output of the insert and is not grounds for a warranty claim.

Before installation, check that the insert is complete, that all mechanisms work and that the body is sound. The insert should be installed on a non-combustible base at least 0.15 m thick. The floor in front of the door must be protected with a strip of non-combustible material that ensures safe use (at least 0.6 m and no shorter than the length of the open door).

When building the casing of a fireplace insert you must:

  • install the insert on surfaces with sufficient load-bearing capacity;
  • allow air to circulate between the walls of the insert and the casing – leave a gap of at least 6 cm between the fire-resistant insulation of the casing walls and the ribbed surface of the insert;
  • ensure air reaches the insert through an air grille above it (the grille must be designed so that it cannot become blocked);
  • ventilate the insert with a pressure relief grille with an area of 200 cm²; the decompression chamber should be 30–50 cm high, measured from the ceiling;
  • keep a distance of at least 150 cm between the front of the insert and combustible materials;
  • remove all external and safety elements;
  • leave the clearances needed for cleaning the insert and its connector.

After installation, the fireplace insert should be handed over with an acceptance report. Leave at least 6 cm between the insert and the insulation (measured from the ribbed surface to the insulation), and 2–3 cm between the upper part of the facade and the elements of the insert body. Missing these clearances can cause damage and loss of the warranty.

Lighting a fireplace insert for the first time

The first fire should be lit only after the building materials used have dried. Do not make a fierce fire the first time, to avoid a sudden change in temperature. During the first firing a special smell appears – this is the protective coating curing. The smell disappears after a few firings. When lighting, open the primary air supply fully and close it gradually as the fire gets going.

Using a fireplace insert

Safety. Take special care when using a fireplace insert because of the high temperature – there is a risk of burns and fire:

  • use the protective glove supplied by the manufacturer when handling the insert;
  • do not let children near the insert unless supervised by an adult;
  • never dismantle the insert or make any changes to its construction;
  • do not put out the fire in the insert with water;
  • a carbon monoxide detector is recommended in the room where the insert is installed;
  • never leave a burning fire unattended;
  • do not use the insert to dry materials (e.g. clothes), including in its vicinity;
  • never burn fuel in an insert that has not been built in;
  • the door must be closed during normal operation.

If soot ignites in the chimney, notify the nearest fire brigade and a chimney sweep. Until they arrive, fight the fire with a powder extinguisher, directing the jet straight into the chimney flue.

Adjusting the air supply

Combustion can be regulated with the controls provided for this purpose:

  • the position of the handle that opens the damper, which regulates the draught;
  • the position of the slide on the front of the ash pan, which regulates the air supply to the bottom of the firebox.

Firewood for fireplace inserts

Fireplace inserts (depending on the model) burn wood or hardwood briquettes. The heating value of wood is 3.5–3.7 kW/kg when its moisture content is below 20%. Only wood with a moisture content of no more than 20% is suitable – this is reached after about two years of storage. Freshly cut wood has a moisture content of 50–60%. Burning it not only doubles fuel consumption but also causes corrosion of the insert’s parts, rapid soiling of the glass and deposits of soot (creosote) in the insert and flue. Use only the recommended fuel. Do not fill the firebox completely – the optimal amount is about one third of its height. Burning anything other than recommended wood, especially waste and liquid fuels, is prohibited.

Maintenance and cleaning

A fireplace insert must be cleaned regularly, paying particular attention to the flue pipes. A technical inspection by a chimney sweep twice a year is recommended. Chimney flues need to be checked for leaks and swept by a chimney sweep once a year, paying particular attention to whether the flue is clear (it may be blocked by birds’ nests, leaves, etc.). Clean the glass only with products intended for this purpose; regular cleaning prevents permanent stains. Use liquids so that the seals of the insert do not get wet. Remove the ash before the ash pan is completely full, so that it does not block the air supply and the cooling of the grate.

Go to Top